Serial board connections
| Section | Item / terminal | Data / description |
|---|---|---|
| Mechanical | Dimensions, all terminals fitted (W × L × H) | 157mm × 216mm × 30mm |
| Dimensions, terminals removed (W × L × H) | 140mm × 216mm × 16mm | |
| Operating temperature | 0 - 55°C | |
| Weight | 446 gr. | |
| Supply | Normal operating voltage | 24VDC (18 - 30VDC) |
| Power failure | 12V 1.2Ah battery; external battery charging | |
| Power consumption | Standby, 24V input | 1,4W |
| Maximum, 24V input | 10,8W; battery charging, programmable inputs/outputs and all call inputs active | |
| Display outputs | Gray / inverted Gray; binary / inverted binary | 22mA output current at 24V |
| 7-segment, common-anode display | 30mA segment current; short-circuit protected | |
| 31,32,02; normal and inverted | 30mA output current; short-circuit protected | |
| Inputs | Assignable terminal inputs (3) | PI1 / PI2 / PI3 |
| Inspection movement buttons | 500 / 501 | |
| QUADSENSE input | LS | |
| Lower / upper forced-limit magnetic switches | 817 / 818 | |
| Door open / close buttons | K20 / DTS | |
| Fan input | FAN | |
| Photocell sensor input | FSL | |
| Door open / close limits | K16 / K19 | |
| Overload / full-load inputs | 804 / 805 | |
| Current for each input at 24VDC | 6,2mA | |
| Programmable relay outputs | Assignable relay outputs (3) | PR1 / PR2 / PR3 |
| Contact switching rating | 3A 250VAC / 3A 30VDC | |
| Calls | 16 calls | Inputs active with (-); LED outputs short-circuit protected |
| Car outputs | Car lamp / car fan | 220VAC; fuse protected (3A) |
| Emergency lighting | 12V (max.200mA) | |
| Alarm button | Active with 0VDC (1000) | |
| Gong output | 8R/0.5W speaker | |
| Buzzer output | 8R/0.5W speaker | |
| Magnetic-switch supply output | MLO (max.200mA); continuous battery-backed output during a power failure | |
| Load-cell connection | Voltage input | AV-AR (0-10V) |
| Current input | AI-AR (4-20mA) |
Original catalogue table
Panel equipment
| Section | Item / terminal | Data / description |
|---|---|---|
| Supply | Supply voltage | 24VDC (20-28VDC) |
| Encoder, built-in card | ENCI, asynchronous | HTL or TTL; 500 - 4096 pulses; incremental |
| ENCA, synchronous | ENDAT / SINCOS / BISS / REZA encoder protocols supported | |
| Serial communication | Landing fixtures | Connect to the CANBUS socket board |
| Car fixture | Connect to the SERIAL_BOARD | |
| Car door | Serial communication with the MITRON COMFORT CANBUS door board | |
| Relay outputs | RA,RC | 1 relay output |
| Signal inputs | DRIVER | 24VDC, 3mA; 6 inputs, 1 output; assignable terminals |
| MAIN_BOARD | 24VDC, 3mA; 4 inputs, 1 output; assignable terminals | |
| SERIAL_BOARD | 24VDC, 3mA; 3 inputs, 3 outputs; assignable terminals. Floor-level magnetic switches: ML1,ML2 | |
| PTC | Motor PTC | T1 and T2 inputs on MAIN_BOARD. If only the motor PTC is connected, T3 and T4 must be bridged |
| Machine-room PTC | T3 and T4 inputs on MAIN_BOARD | |
| Braking-resistor PTC | T3 and T4 inputs on MAIN_BOARD | |
| Door bridging | Door-bridging circuit | Located on the board |
| Cooling | Panel cooling | X2 fans; aluminium heat sink; ventilation at the bottom and top of the enclosure |
| Contactor | Supply | 42 VAC |
| Safety circuit | Supply | 42 VAC |
| Software update | AVIREX KEYPAD | Software updates using the AVIREX KEYPAD product |
Original catalogue table
Drive technical tables
| Specification | 7.5 kW | 11 kW | 15 kW |
|---|---|---|---|
| Asynchronous model | AVRXAS18A-1 | AVRXAS26A-2 | AVRXAS35A-3 |
| Synchronous model | AVRXSN18A-1 | AVRXSN26A-2 | AVRXSN35A-3 |
| Nominal output current (Inom) | 18A | 26A | 35A |
| Maximum output current | 27A | 39A | 52,5A |
| Braking resistor (BR-,BR+) | 50Ω 1500W | 40Ω 2000W | 33Ω 3000W |
Common drive specifications
| Specification | Data |
|---|---|
| Type | AVIREX COMPACT FX |
| Input (L1,L2,L3) | AC 3-phase, 340V-440V, 50/60 Hz |
| Output (U,V,W) | AC 3-phase, 0V-400V, 0-300 Hz |
| Internal EMC filters | No internal EMC filter |
| Remote access | Wi-Fi module (2.4 GHz) |
| User interface | LCD display; 2 lines, 16 characters |
| Rescue input (ES1,ES2) | 220VAC single-phase mains input |